- Between bearing pump, single stage
- Double suction impeller pump
- Casing is center line mounted and with case wear ring
- Removal of rotor or inner elements is possible without disconnecting suction or discharge piping or moving the driver.
- Enclosed impellers with wear rings.
- Inherent axial thrust balancing because of double suction impeller.
- Impeller is keyed to the shaft
- Impellers located using impeller nut with threads to tighten by liquid drag on the impeller during normal rotation.
- Shaft supported on antifriction bearings
- DE – A roller bearing with C3 clearance
- NDE – A pair of angular contact ball bearing in back to back arrangement
- Thrust bearing is located on the shaft with the help of lock washer and lock nut.
Pump Casing
The casing is radially split and centerline mounted on pedestals. This reduces the effect of non-uniform thermal expansion of casing caused when pump is subjected to high temperature working liquid and/or external nozzle loads.
All casings are double volute type to take care of radial load generated during operational of the pump. The double volute design minimizes shaft deflection and eliminates unpredictable bearing and seal failures.
Nozzle orientation arrangement & pressure ratings Possible suction & discharge nozzle arrangements available are Top‐Top, Side‐Top or Side‐Side. Depending on customer’s requirement pump with any of the above configurations can be designed & manufactured. Depending upon MAWP of pump, nozzle rating according to ASME B16.5 ranging from Class #150 to #600 with Raised Face (RF) & with Ring Type Joint (RTJ) above Cl.#900 are available.
Auxiliary Connections
Pumps with Top‐Top & Side‐Top nozzle orientations are with self‐Venting arrangement whereas drain connection of ¾ inch is taken out from the bottom of casing & flange connection is provided within battery limit. Drain connection with Flanged + Valve arrangement can be provided if specified.
Casing Gasket An 18-8 stainless steel spiral wound gasket with non-Asbestos filter is provided between the casing cover and the pump casing.
Stuffing box
The stuffing box is deep enough to accept various seal designs including tandem and double seals. Pump with conversion kit can also be supplied at site. After reaching pump to site this conversion kit can be removed & job specific seal can be assembled. Water cooled or steam heated stuffing box designs are available at extra cost when specified or required. Hydro‐test pressure for standard water jacket is 9.8 bar (G).
Impeller
The impeller is a closed & is double suction type. It is provided with both front and back wear rings fixed with grub screw to ensure positive fitment of wear rings on impeller hub. Being a double suction design it helps in balancing of axial thrust developed during operation of pump. It also helps in reducing the suction specific speed of the pump which sometimes becomes hurdle in technical acceptance of model. Optional Inducer design is also available for critical NPSH requirement or under critical suction conditions. These impellers are located on shaft using impeller nut with threads to tighten by liquid drag on the impeller during normal operation of pump.
Impeller wear-rings
The impeller wear rings are made in same material as that of impeller & held on with an interference fit and secured in positions with grub screws radially to ensure positive fitment on impeller hub. In case process liquid contains solid particles, then serrations or wear ring flushing can be provided to avoid choking of these solid particles in wear rings.