
Published 1 November 2026 · Dr. Pump & Engineering Co., Ltd., Pathum Thani, Thailand
A fire pump is the heart of any sprinkler or hydrant system: when a fire starts, it must deliver the right flow at the right pressure, every time. Our new animated video shows exactly what happens inside a fire pump room, and how Dr. Pump & Engineering supplies, installs and services FM/UL listed fire pump systems across Thailand.
Key takeaways
- Dr. Pump & Engineering Co., Ltd. supplies FM/UL listed fire pump systems built to NFPA 20, from its engineering and assembly base in Lat Lum Kaeo, Pathum Thani, Thailand.
- Pump types: vertical turbine (VT), horizontal split case (SC) and end suction (ES), with electric or diesel drivers.
- Fire pump brands: Bombas Ideal, Pumpsense, RFP, Peerless, Dr Pump and RPS.
- Firetrol and Tornatech FM/UL controllers are held in stock; WEFLO main relief valves and GVI flow meters complete the pump room.
- Local installation, commissioning, service, repair and retrofit, with 34 fire pump projects across Thailand: hospitals, government, industry and tourism.
Video: how a fire pump room works
Read the video transcript
0:00 Dr. Pump & Engineering: FM/UL fire pump systems and NFPA 20 solutions, from stock in Thailand.
0:05 Inside a split case fire pump room: water storage tank, electric fire pump, diesel fire pump, jockey pump and controllers. A sprinkler opens, the jockey pump starts, then the main fire pump starts and delivers water to the sprinklers while the diesel pump stays on standby.
0:19 A vertical turbine fire pump installation: the diesel controller starts the engine, the right-angle gear drive turns the line shaft, the bowls lift water from the sump to the system, and the relief valve sheds excess pressure.
0:34 Brands we represent: Bombas Ideal, Pumpsense, RFP, Peerless, Dr Pump and RPS fire pumps; Firetrol and Tornatech controllers from stock; WEFLO relief valves and GVI flow meters.
0:46 Local service and repair from our engineering and assembly plant in Pathum Thani.
0:55 Capabilities: pump types, valves and meters, controllers, service, quality standards and wider flow solutions.
1:06 34 fire pump projects across Thailand in healthcare, government, industry and tourism.
1:18 Reference project: Siam Gas jetty, 5,000 USGPM, 100 m head, 506 kW diesel, NFPA 20.
1:26 Contact: askpumpdr.com, firepumpthai.com, pumpsensethai.com, +66 93 989 6541.
How a fire pump system responds to a fire
In a typical split case fire pump room, the system moves through five stages:
- Standby. The jockey pump keeps the sprinkler and hydrant pipework pressurised, and the controllers sit on automatic.
- Pressure drop. When a sprinkler opens or a hydrant is used, system pressure falls. The jockey pump starts first, but it cannot keep up with fire flow.
- Main pump start. The electric fire pump controller starts the main pump. Water is drawn from the fire water storage tank and pushed into the discharge header and riser.
- Diesel back-up. The diesel engine-driven fire pump stands by on its own controller, ready to take over if electric power fails.
- Pressure control and testing. The main relief valve sheds excess pressure, and a flow meter on the test header lets engineers check pump performance without flowing water through the system.
Vertical turbine fire pumps: lifting water from a sump
Where the water source sits below the pump room, such as a jetty, river intake or underground pit, a vertical turbine (VT) fire pump is the standard answer. Our second animation follows a typical diesel-driven VT installation:
- A vertical turbine fire pump is used where water must be lifted from below the pump: a sump, wet pit, well, river or sea water intake.
- The diesel engine drives the pump through a flex shaft and right-angle gear drive on top of the discharge head; an electric vertical motor can be used instead.
- The column and line shaft carry water up from the bowl assembly and basket strainer submerged in the sump.
- The pump room also includes the fuel tank, batteries, controller, silencer, pressure gauge, relief valve and cone, check and OS&Y gate valves, flow meter test header and hose valve header.
Fire pump brands we represent in Thailand
Dr. Pump & Engineering represents listed fire pump, controller and accessory brands, so a complete pump room can be specified and supported by one local team:
| Brand | Origin | Products | Listing |
|---|---|---|---|
| Bombas Ideal | Spain | Fire pumps | FM / UL |
| Pumpsense | India & Thailand | Fire pumps | FM / UL / NFPA 20 |
| RFP | China | Fire pumps | FM / UL |
| Peerless | USA | Fire pumps | FM / UL |
| Dr Pump | Dr. Pump & Engineering | Fire pumps | NFPA 20 |
| RPS | Australia | Pumps | NFPA 20 |
| Firetrol | — | Fire pump controllers (from stock) | FM / UL |
| Tornatech | — | Fire pump controllers (from stock) | FM / UL |
| WEFLO | — | Main relief valves | FM / UL |
| GVI | — | Fire pump flow meters | FM / UL |

Local service and repair, supported in Thailand
Fire pumps must work after years on standby, so local support matters as much as the equipment. From our engineering and assembly plant in Lat Lum Kaeo, Pathum Thani, our engineers provide:
- Selection & specification: Application-led pump selection from flow, head, suction conditions and driver.
- Supply from stock: Firetrol and Tornatech FM/UL controllers held locally for fast delivery.
- Installation & commissioning: Fire pump sets installed and commissioned to NFPA 20.
- Service & maintenance: Servicing of pumps, diesel and electric drivers and controllers.
- Repair & overhaul: Diagnosis and repair of fire pumps, drivers and controllers in Thailand.
- Refurbishment & retrofit: Upgrading existing pump rooms with listed pumps, controllers and valves.
Project references: 34 fire pump projects across Thailand
- Healthcare (19 projects): Phrapokklao Hospital (Chanthaburi), Uttaradit Hospital, Mukdahan Hospital, Buddhasothorn Hospital (Chachoengsao), Department of Disease Control (Nonthaburi) and 14 more hospitals and health buildings.
- Public & government (5 projects): Office of the Permanent Secretary for Defence, Royal Thai Police, Office of the Consumer Protection Board, Ubon Ratchathani Provincial Court, Loei Rajabhat University.
- Commercial & industrial (8 projects): Siam Gas & Petrochemicals (jetty 7C), Viscofan Thailand, Chicony Electronics (Thailand), BHP factory and warehouse (Rayong), Ratchaburi Industrial Estate flood protection, Num Rubber & Latex, United Center, Ekachai Hospital.
- Tourism & education (2 projects): Bang Saen underwater world learning centre and Bang Saen Beach multipurpose building (Chonburi).
Featured project: Siam Gas jetty. NFPA 20 fire water pumps for Siam Gas & Petrochemicals PCL at jetty 7C, rated 5,000 USGPM at 100 m head and driven by 506 kW diesel engines.
Bombas Ideal fire pumps, which we represent, also protect international landmarks such as the Prat Airport control tower in Barcelona, the Guggenheim Museum in Bilbao and the Harbour of Valencia, as well as PTT facilities in Rayong.
Frequently asked questions
What is a fire pump room?
A fire pump room houses the pumps, drivers, controllers and valves that boost water pressure for sprinklers and hydrants. A typical room has a main electric fire pump, a diesel engine-driven back-up pump, a small jockey pump that maintains pressure, a controller for each pump, a relief valve, and a test header with a flow meter.
What does FM/UL listed mean for a fire pump?
It means the pump or controller model has been independently tested and listed by UL and approved by FM Approvals for fire protection service. Many insurers, consultants and authorities in Thailand specify FM/UL listed equipment, installed to NFPA 20.
What is the difference between a vertical turbine and a split case fire pump?
A vertical turbine fire pump lifts water from a source below the pump, such as a sump, pit, well or sea water intake. A horizontal split case fire pump needs water to flow into it under positive suction, usually from a storage tank, and is easy to service because the casing opens horizontally. End suction pumps are a compact option for smaller flows.
What does a jockey pump do?
A jockey pump is a small pump that keeps the fire protection system pressurised and makes up for minor leaks, so the main fire pump does not start unnecessarily.
Which fire pump brands does Dr. Pump & Engineering supply in Thailand?
Bombas Ideal (Spain, FM/UL), Pumpsense (India and Thailand, FM/UL/NFPA 20), RFP (China, FM/UL), Peerless (USA, FM/UL), Dr Pump (NFPA 20) and RPS (Australia, NFPA 20). Controllers are Firetrol and Tornatech (FM/UL, from stock), with WEFLO main relief valves and GVI flow meters (FM/UL).
Does Dr. Pump service and repair existing fire pumps?
Yes. Dr. Pump & Engineering provides local installation, commissioning, service, repair, overhaul and retrofit of fire pumps, diesel and electric drivers and controllers from its base in Pathum Thani, Thailand.
How do I get a fire pump quotation in Thailand?
Call or message +66 93 989 6541 (also LINE and WhatsApp) with your required flow, pressure (head), water source and preferred driver, or visit askpumpdr.com, firepumpthai.com or pumpsensethai.com.
Talk to a fire pump engineer
Send us your required flow, pressure (head), water source and preferred driver, and we will recommend a listed fire pump package.
- Phone: +66 93 989 6541 (LINE and WhatsApp +66939896541)
- Address: 88/17 Village No. 7, Lat Lum Kaeo, Pathum Thani 12140, Thailand
- Websites: askpumpdr.com · firepumpthai.com · pumpsensethai.com
สรุปภาษาไทย
บริษัท ด็อกเตอร์ปั๊ม แอนด์ เอ็นจิเนียริ่ง จำกัด จำหน่ายและติดตั้งระบบปั๊มดับเพลิงมาตรฐาน FM/UL ตามมาตรฐาน NFPA 20 ทั้งปั๊มเทอร์ไบน์แนวตั้ง (VT) ปั๊มสปลิทเคส (SC) และปั๊มเอ็นด์ซักชั่น (ES) จากแบรนด์ Bombas Ideal, Pumpsense, RFP, Peerless, Dr Pump และ RPS พร้อมตู้ควบคุม Firetrol และ Tornatech พร้อมส่งจากสต็อก วาล์วระบายแรงดัน WEFLO และมาตรวัดอัตราการไหล GVI ให้บริการติดตั้ง ทดสอบระบบ บำรุงรักษา และซ่อมแซมโดยทีมวิศวกรในประเทศไทย ติดต่อ 093-989-6541